Back to top

PTFE Lined Wafer Check Valve

PTFE Lined Wafer Check Valve
PTFE Lined Wafer Check Valve

PTFE Lined Wafer Check Valve Specification

  • Material
  • SGI
  • Connection Type
  • Wafer Type (Sandwiched between flanges)
  • Valve Size
  • 25NB to 400NB
  • Valve Type
  • Non-return / Check Valve
  • Structure
  • Wafer Type, Swing Check
  • Sealing
  • PTFE / FEP / PFA / Teflon Lined
  • Application
  • Corrosive chemical processes, pharmaceuticals, water treatment, and food industries
  • Type
  • PTFE Lined Wafer Check Valve
  • Power
  • Manual (Non-powered)
  • Size
  • 25NB to 400NB
  • Pressure
  • Up to 10 Bar (Standard)
  • Media
  • Acidic, Alkaline, Corrosive Fluids, Water, Chemicals
  • Product Type
  • Lined Wafer Check Valve
  • Port Size
  • 25NB to 400NB
  • Color
  • As Per Requirements
  • Temperature
  • -20C to +180C
  • Disc
  • Stainless Steel/PTFE/FEP Lined Disc
  • Leakage Class
  • Class VI, Zero Leakage
  • End Connection
  • Wafer Flanged as per ASME B16.5 (Class 150/300), DIN/BS available
  • Face to Face Dimension
  • As per ANSI B16.10/ DIN/BS standards
  • Mounting Orientation
  • Sandwich type, between two flanges
  • Installation
  • Horizontal/Vertical (Upward flow)
  • Gasket Compatibility
  • PTFE/Non-asbestos
  • External Coating
  • Epoxy Painted for better corrosion protection
  • Body Test Pressure
  • 1.5 times rated pressure
  • Seat Test Pressure
  • 1.1 times rated pressure
  • Standards
  • Design as per API 594
  • Lining Thickness
  • Minimum 3 mm (Uniform)
 

PTFE Lined Wafer Check Valve Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Against Delivery (CAD), Cash Advance (CA), Cheque
  • Delivery Time
  • 5-10 Days
  • Main Domestic Market
  • All India
 

About PTFE Lined Wafer Check Valve

Swing Type PTFE Lined Wafer Check Valve is suitable to mount between two flanges of ANSI B 165 and are ideal for use in totally lined piping system in corrosion application This valve can be mount in either direction  The angled seat allows the valve to be installed in both horizontal and vertical applications

Outstanding Chemical Resistance and Zero-Leakage Performance

Designed for rigorous duty in corrosive chemical and process media, this check valve boasts a uniform 3 mm PTFE lining and Class VI sealing, delivering absolute zero leakage. The non-return swing check mechanism ensures dependable prevention of backflow, while compatibility with various aggressive fluids provides versatile system protection.


Easy Installation and Broad Compatibility

The valve utilizes a wafer-type design, making it simple to install between standard flanges per ASME B16.5 (Class 150/300), DIN, and BS standards. With both horizontal and vertical (upward flow) mounting options, it is adaptable to various pipeline configurations and ensures a secure, leak-free fit.

FAQs of PTFE Lined Wafer Check Valve:


Q: How do I install the PTFE Lined Wafer Check Valve in my pipeline?

A: The valve is designed for sandwich-type mounting between two flanges, compatible with ASME B16.5 (Class 150/300), DIN, and BS standards. It can be installed in horizontal pipelines or vertically for upward flow, making it highly versatile for different system layouts.

Q: What benefits does PTFE lining provide in this valve?

A: The minimum 3 mm uniform PTFE lining offers exceptional chemical resistance, preventing corrosion and contamination when handling aggressive acids, alkalis, and other hazardous fluids. This ensures durability and extends the valves operational life.

Q: When should I consider using this valve in my process system?

A: Consider this valve for applications involving corrosive chemical processes, pharmaceuticals, water treatment, or food industries where non-return functionality, zero leakage, and chemical compatibility are critical for safety and efficiency.

Q: Where can the PTFE Lined Wafer Check Valve be utilized?

A: It is suitable for installations in chemical processing plants, pharmaceutical manufacturing, water treatment facilities, and food-grade applications, particularly where aggressive fluids require robust isolation and backflow prevention.

Q: What testing standards are followed to ensure valve reliability?

A: The valve is designed according to API 594. It undergoes body test pressure at 1.5 times the rated pressure and seat test at 1.1 times the rated pressure, ensuring full compliance and guaranteed performance under demanding conditions.

Q: What types of sealing options are available?

A: Sealing is available in PTFE, FEP, PFA, or Teflon-lined options, each providing optimum leakage protection and compatibility with a wide range of aggressive media, enhancing safety and service reliability.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PTFE Lined Valves Category

Ptfe Lined Ball Check Valve

Ptfe Lined Ball Check Valve

Price 3500 INR / Piece

Minimum Order Quantity : 1 Piece

Size : 15NB to 200NB

Color : As Per Requirements

Product Type : Lined Ball Check Valve

PTFE Lined Flush Bottom Tank Valve

PTFE Lined Flush Bottom Tank Valve

Price 38000 INR / Piece

Minimum Order Quantity : 1 Piece

Size : 80NBX50NB, 100NBX80NB,150NBX100NB

Color : As Per Requirements

Product Type : Lined Flush Bottom Tank Valve

Temperature : PTFE Lined Temperature 240C Celsius (oC)

PTFE Lined Gate Valve

PTFE Lined Gate Valve

Price 10000 INR / Piece

Minimum Order Quantity : 1 Piece

Size : 50NB to 100NB

Color : As Per Requirements

Product Type : Lined Gate Valve

Temperature : PTFE Lined Temperature 240C

PTFE Lined Full View Sight Glass

PTFE Lined Full View Sight Glass

Price 2500 INR / Piece

Minimum Order Quantity : 1 Piece

Size : 15NB to 200NB

Color : As Per Requirements

Product Type : Lined Full View Sight Glass

Temperature : PTFE Lined Temperature 240C Celsius (oC)



RADIANT HITEMP & THERMO CABLES
GST : 24AKGPP2229J1Z5